18 Operating Manual for GPIB for XHR/XFR Series Power Supply
Table 1.6 Specifications for XHR 1000 W Series Supply with GPIB Interface Installed (100 V to 600 V)
Models 100-10 150-7 300-3.5 600-1.7
Program Resolution
Voltage
Current
OVP
15.4mV
3.92mA
15.4mV
23.1mV
2.52mA
23.1mV
46.2mV
1.26mA
46.2mV
92.4mV
0.56mA
92.4mV
Program Accuracy
1
Voltage
Current
OVP
1. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 20-50 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 50mV ± 0.12% of the set voltage of 10 volts.
150mV
±0.35%
140mA
±0.15%
800mV
225mV
±0.35%
120mA
±0.1%
1.5V
225mV
±0.35%
80mA
±0.1%
3.0V
250mV
±0.35%
80mA
±0.1%
6V
Readback Resolution
Voltage
Current
15.4mV
3.92mA
23.1mV
2.52mA
46.2mV
1.26mA
92.4mV
0.56mA
Readback Accuracy
1
Voltage
Current
150mV
±0.35%
140mA
±0.15%
225mV
±0.35%
120mA
±0.1%
225mV
±0.35%
80mA
±0.1%
250mV
±0.35%
80mA
±0.1%