Xantrex Technology FP 3000-12 Portable Generator User Manual


 
38
Installation Option #1
The inverter is used in a Single Input/Single Output mode. Up to 30 amps is transferred
through the FP3000-12 with the charger sharing power with all of the AC loads.
In this installation example, a single 30-amp shorepower source is available and all AC loads are
supplied power through the inverter in charge/transfer mode, or by the inverter in invert mode.
The charger shares power with the AC loads and can transfer up to 30 amps. The AC input
power must be supplied through a 30-amp branch rated main breaker.
In this type of system, the panel loads would normally not include any heavy loads such as
space heaters, stove, water heaters, air conditioners, AC to DC converters, or other battery
chargers. If these types of loads are present, they should be turned OFF when the inverter
power is being used to prevent overloading the inverter or rapidly discharging the battery
bank. To avoid the need for this manual form of energy management, installation option #2
should be considered.
If a generator is installed in the system, a break-before-make AC transfer switch is used to se-
lect between shore or generator power. The transfer switch AC output is then routed to the input
of the inverter/charger.
INSTALLATION OPTIONS