Xantrex Technology FP 3000-12 Portable Generator User Manual


 
27
• Remove the positive (+) battery cable
terminal cover from the unit and attach the
battery cable. Tighten the battery terminal bolts
to a torque value between 160 inch-pounds
and 180 inch-pounds. Replace the cover for
the positive terminal.
The negative (-) cable should be connected
directly to the negative post of the house or
auxiliary battery bank or the ground side of a
current shunt. Tighten securely.
The positive (+) battery cable must be fused
and connected to the positive post of the
house or auxiliary battery bank, or through a
selector switch to one or more battery banks.
A spark may be generated when the final
battery connection is made. This is normal; do
not be alarmed. However, do not make the final
connection in the presence of flammable fumes.
If multiple batteries are used, the
interconnecting jumper cables must be the
same AWG or larger as those connected to
the inverter/charger.
NOTE: If installing in a vehicle, do not use the
vehicle frame as the negative conductor.
If multiple battery banks are to be charged, a
battery bank selector switch can be installed,
allowing the banks to be charged either
individually or simultaneously. A solenoid can
also be used.