2–22 445-0127-01-01
5. Use the black Terminal Cover to fasten the 5/16” ring type connector
on the other end of the negative (black or marked negative) cable to
XPower 1500’s negative High Power DC Terminal (black). Again,
tighten firmly, but do not over tighten.
6. To disconnect the external battery, simply follow steps 2-5 in reverse
order.
Important:
Unless the external battery is a lead acid, 17 amp-hour, AGM
design, it must be disconnected from XPower 1500 prior to recharging XPower
1500’s internal battery pack. The AC Charger and DC Charging Cable supplied
should only be used to charge (a connected) external battery that has the same
amp-hour rating and design as XPower 1500’s internal battery pack. If your
external battery is not the type specified above, disconnect it from XPower 1500
and charge it with a separate battery charger.
WARNING: Personal injury
Disconnect the external battery prior to moving XPower 1500 to prevent damage
to the connecting cables or the external battery, and to avoid possible injury to
you or another person.