Vita Spa L100 Hot Tub User Manual


 
DI A G NO S T I C & TROUBL E S HOOT I NG
SYMPTOM
Spa Inoperative
Spa Side Inoperative
MESSAGE
BLO
CP
FLO
CS
F1 or F2
HC
HP
LB
LP
O3U
P1
P2
Pb
PS
SS
LS
ME A N IN G
Power failure outside of spa.
Spa Side could be locked.
Blower Error
HE ET pump may be faulty.
Lack of Flow:Heater disabled
Current Sensor
Blown Fu s e
Heater Error
High Vo l t a g e
Light Error
Low Vo l t a g e
Ozonator Error
Pump 1 Error
Pump 2 Error
Spaside Communication
Pressure Switch Error
Heater Sensor
Water Sensor
AC T I O N
Check power source Breaker and GFCI;
Reset breaker/GFCI. Call Electrician if it
will not start.
If lock icon is visible, unlock by depressing
the “ UP ” button for 5 seconds
Check fuse 3 and then verify that the
blower motor is plugged in.
Check that HE ET pump is plugged in.
Remove filter. If “FLO” disappears, clean
f i l t e r .
Check that current sensor board is plugged
into circuit board.
Replace fuse 1 or fuse 2
Replace heater
High power (voltage) observed. Check
power connections and rerun diagnostic
t e s t
Replace underwater light bulb
Low Power (voltage) observed. Check
power connections and rerun diagnostic
t e s t
Replace oz o n a t o r
Check plug for Pump 1
Check plug for Pump 2
Check topside connection and remote
panel connections to power board.
Replace Pressure Switch
Replace Sensor
Replace Sensor
IF ANY ERRORS ARE FOUND, THE FOLLOW ING MESSAG ES MAY BE DISPLAY E D :
PAGE 33