Unigreen Super Spalliera Blower User Manual


 
unigreen 9
4.2 PRELIMINARY CHECKS
When you receive the machine, check that it is complete and no parts are
missing.
If there are any damaged parts, inform your local reseller or UNIGREEN
directly in good time.
When the machine is delivered, make sure you ask:
a) that the machine is delivered with all of its parts fitted and that the fitting
meets the requisites in table N° 18a (page 31).
This procedure is necessary because for reasons of space during
transportation the machine is often delivered partially dismantled.
b) that it is tested in your presence in particular checking:
= that the suction filter and the inside of the tank are clean and free of work
residues.
= that the connections are made correctly following the basic layout (FIG. N°
16, page 16).
= that the hose clips and all the unions and connections are tightened
properly.
= that all of the protective covers are fitted solidly to the machine, in
particular the protective cover of the power-takeoff of the pump.
= that the multiplier is sufficiently supplied with lubricant oil.
= that the zone where the fan turns hasn’t been bent by knocks during
transportation.
4.3 TRANSPORTING AND MOVING THE MACHINE
Every time you have to lift the machine, before starting the operation, always
make sure the lifting gear and the relevant tools and equipment (cables, hooks,
etc..) are suitable for lifting the load and check the stability of the same.
It is forbidden to unhook and move the machine with the tank full.
The dry weight of the machine at the maximum level of fitting and with all the
accessories allowed is stamped on the nameplate (FIG.2); use slings and
lifting gear with a adequate load-bearing capacity (FIG.3).
Never lift or move the mistblowers by hand if there is liquid in the tank. The
machine will weigh more and the movement of the liquid can change the centre
of gravity causing uncontrolled movements.
We recommend using slings as shown in the figure, the lifting points to use on
the machine are indicated with the relevant symbol.
Don’t lift the machine with the forks of a forklift truck because the machine can
tip over due to the overhanging weight of the blower group.
Don’t pass or stand under the machine when it is being lifted.
4.3.1 TOWED ATOMISERS
PARKING
Don’t stand the atomiser on unstable ground or steep slopes, the machine is
designed to be parked safely on compact ground with a slope of up to 8.5°
MOVING
To lift the machine, follow the instructions above.
FIG.3
This symbol
identifies the
coupling points
of the machine
Only move and lift the machine
with the tank empty