Toro TDC-100/200 Sprinkler User Manual


 
Station Settings allows you to set parameters specific to each station.
Use the Up or Down Arrows to navigate through the menus.
Use the Left and Right Arrow Keys to advance to the next entry field on the same menu line.
Use the Input Dial to select values when editing.
S01 Select the station you want to edit in this field. Choose from
Station 01 through the controller maximum station count of
200.
100% If weather or other condition requires irrigation program
modification, it can be easily adjusted by changing the percent
adjustment. Station operation can be reduced to 000% (Off) or
increased up to 900%. 100% represents standard operation.
Decoder Addr: Enter the decoder’s 5-digit address code that corresponds to
the selected station.
DecSta: If using a 2 or 4-station decoder, select the decoder station to
designate to the selected station.
Decoder Station Color Codes
RED = Station 1, GREEN = Station 2, ORANGE = Station 3,
BLUE = Station 4
Path: Select the correct wire path (1 or 2). Enter wire path 01 for
stations connected to the 1st daughter board and wire path 2
for the 2nd daughter board.
Disable: Use this function to disable station operation by selecting Yes
from the menu. Resume station operation by selecting No from
the menu.
Set Sta as a MV: Use this function to designate the station to operate as a Master valve (up to 6) by selecting Yes.
Suggestion: Assign station number that will not interfere with your programming such as
100 or 200.
Assn Sta to MV: Use this function to assign a station to run with a specific master valve (Not available if the
station is designated as a Master Valve).
Sched Today: This function will display the total scheduled station runtime for the current day.
Water Today: This function will display the total station runtime that has occurred for the current day.
Is Switch: Use this function to assign the selected station to a switch. When the switch (station) is
activated, the Master Valve or Pump will not actuate.
Hold Sta: Use this function to delay operation for this station. Select the hold duration from 01–30 days,
Permanent or None. This function is useful when a specific station needs to be deactivated
without affecting any of the programs.
Cycles: (For Future Use)
Edit Name: Use this function to assign a name description to the station. In Golf mode, the naming format is
XX-AA-YYY, where XX represents the golf course hole number, AA represents the area
description acronym and YYY represents the sprinkler number within the area. By following the
naming format, you can easily figure out where and what area the station is watering.
Area Description Acronym Listing
GR = Greens DR = Driving Range TE = Tee CL = Club House FW = Fairways
LA = Landscape RF = Rough PG = Putting Green AP = Approaches MS = Misc.
In Commercial mode, assign a 10-character name of your choice, such as “shrubs” or
“back lawn”.
Flow Sens: (For future use.)
Output Volts: Use this function to select the controller’s output voltage. Select between 15 or 20 volts DC.
Important! For proper operation, install compatible DC-latching solenoids only.
Station Settings
1100
FlowSens:03StaFlo200
Output Volts: 15
Is Switch: NO
Hold Sta : NO
Cycles : 01 times
Edit Name: 01TE020
Set Sta as a MV: NO
Assn Sta to MV: 000
Sched today: NONE
Water today: NONE
S100 100% 1STSTLAWN
Decoder Addr: 38684
Dec Sta: 4 Path: 2
Disable: No