Topcon GTS-822A Telescope User Manual


 
5-23
5 PROGRAM MODES
5.7 External Link
You can use compatible communication command of AP-L1A for GTS-820A series. In this process
carry out setting for remote control system RC-2II using together.
5.7.1 Starting compatible communication program of AP-L1A
5.7.2 Setting for the communication
Decide transmit course and parameters before executing communication.
(1)Setting communication course
Select a communication course according to the using optional device.
1) Cable : In case connecting personal computer or other than Topcon's designated wireless
modem to the RS-232C connector.
2) RADIO MODEM : In case connecting Topcon's designated wireless modem.
3) RC :In case carrying out optical communication using with the remote controller system
RC-2II.
Operating procedure Operation Display
1
Press the [F6](MORE) key to get the next
page.
[F6]
2
Press the [F3](EXT.LINK) key.
The compatible program EXTERNAL LINK
will start.
[F3]
Operating procedure Operation Display
Execute Section 5.7.1“Starting compatible
communication program of AP-L1A” to start
[EXT.LINK] of compatible communication
program of AP-L1.
1
Press the [F2](Setting) key.
[F2]
2
Press the [F1] key to select [CABLE/RADIO
MODEM/RC]
[F1]
Programs
F1 BS p 4/7
F2 STORE p
F3 REM p
F4 MLM p MORE
Programs
F1 LINE P 7/7
F2 OFF SET P
F3 EXT.LINK P
MORE
EXTERNAL LINK
1 Execute
2 Setting
EXTERNAL LINK
1 Execute
2 Setting
Setting
1 CABLE/RADIO MODEM/RC
2 PARAMETER(CABLE)
3 PARAMETER(RC)
4 PARAMETER(RADIO MODEM)
CABLE/RADIO MODEM/RC
CABLE
SET
EXIT