Taylor Pool Heat Pump Swimming Pool Heater User Manual


 
WATER INLET AND OUTLET CONNECTIONS
For all Eclipse (MP) models, connection pipes are 1 1/2 inches in diameter. For all
Generation (CP) models, the connection pipes are 2 inches in diameter. For all the pool
heaters, we recommend (obligatory for the Eclipse series) the installation of a set of valves
allowing to isolate the pool heater from the filtration system when necessary. (See the drawing
below.) Moreover, you have to make sure that your pool heat pump may be disconnected from
the pool pipes without having to stop the water pump or without losing great quantities of water.
To adjust the water flow going through the pool heater, please adjust the by-pass valve (a)
in the following way:
MP30 - MP50 : 3/4 opened
MP70 : 1/2 opened
All CP’s : Closed - the internal calibrated valve regulates the water flow, exception
for those who have a water pump of 2hp or greater, adjust the valve to obtain the flows listed
below.
If the previous settings are not respected, the pump or the pool heater may be over-
charged and result in failure of your equipement.
Your water pump must provide the quantity of water indicated in the table below. These
numbers must be used for each pool heat pump installed. A flow meter must be installed on the
water inlet of the pool heater to know the exact water flow. Caution : many flow meters require a
long distance of straight tubing on the inlet side to offer an adequate measurement.
For your own security, and to ensure proper operation of the unit, the water connec-
tion must be performed by a qualified person as per all applicable national, provin-
cial, state or local codes.
Minimum Ideal Maximum
Eclipse 15 GPM(US) 20-30 GPM(US) 50 GPM(US
)
Generation 25 GPM(US) 40-50 GPM(US) 65 GPM(US
)
Front View
W
ater Outlet
Water Inlet
Set of valves
a
a
GMP(US) : American gallons (3,78l) per minute
5