Sundance Spas Portofino Series Hot Tub User Manual


 
9.0 Operating Instructions
The spa control system has automatic functions that
operate upon start-up and normal operation to
protect the system. Upon power up, the readout
displays the following information:
1. Control displays current software release
(e.g. 3.54), then;
2. Control panel displays “888” and all indicator
LEDs are lit, permitting visual inspection of all
display segments and indicator lights for proper operation.
3. After the initial start-up sequence ends actual water temperature
is displayed. If water temperature at this time is less then the
factory default temperature setting of 100 °F (38 °C), the
circulation pump and heater will turn on and run until the water
temperature rises to the factory default temperature setting.
Then the heater turns off and the circulation pump remains on for
24-hour operation.
Note: it is common for the heater to turn on
after the spa is first filled because tap water is often very cold.
9.1 Setting Water Temperature
The spa’s thermostat provides optimum control of water
temperature. The temperature setpoint (set temperature)
can be adjusted from 65 °F to 104 °F (18 °C to 40 °C).
To raise the set temperature, press the WARMER
arrow button. To lower the set temperature, press the
COOLER
arrow button.
Note: The first press of either WARMER
or COOLER button displays the set temperature.
9.2 Pump Button
The JETS button activates the functions of the pump.
The first press activates low speed, the second press
activates high speed, and the third press shuts the pump
off. The pump has a twenty-minute default when
manually activated.
9.3 Light Button
The LIGHT button activates the spa light when pressed.
12
Startup
Sequence
1.
2.