Sundance Spas 880, 850 Hot Tub User Manual


 
Page 40
ENGLISH
16.0 Electrical Wiring Diagram
Export 50Hz
230 VAC, 1-Phase, 50 Hz;
1 Pump = 12A/24A; 2 Pump = 18A/30A
USE MIN. 6 AWG (10 mm
2
) COPPER CONDUCTORS ONLY
SENSORS 800 LCD PANEL
J8 J6 J7
J3
OPTIONS
FLOW SWITCH
HI - LIMIT / FREEZE SENSOR
TB4
TB3
G
1
TB2
2 1
1
2
PUMP 1
PUMP 2
HI
HI
TEMPERATURE
SENSOR
SPA
LIGHT
TB7
From TB1
TB1TB2
UV or CD
Ozonator
(Optional)
Circulation
Pump
TB5
2
1
1
TB6
2
1
1 2 3
20A,
250V
SC-20
F1
N
N
N
N
N
LN
NN
L
LLLL
L
L
N
L
N
Red
Black
STEREO
(Optional)
Power Supply
HEATER
2.7kW, 230 VAC
System Control Panel
BLOWER
L
N
To Heater: For 2 Breaker
System, Remove These Wires
And Connect to Top of TB2
TB1
JP20
JP19
JP9
1
1
3
5
7
9
1
3
5
7
9
11
13
See Chart
(Page 39)