Sundance Spas 880, 850 Hot Tub User Manual


 
REFILLED. IF YOU SUSPECT THAT THIS IS THE CASE, SEE THE
INSTRUCTIONS ON PAGE 37 UNDER “PUMP DOES NOT OPERATE...”
Panel sensors have been pressed too many times in a short
period of time. Because this could cause excessive wear on
equipment components, panel sensors are temporarily
deactivated. Panel sensors will automatically re-activate if no
sensor is pressed for 30 seconds.
Circuit board temperature has exceeded acceptable limit. This
message will disappear when the circuit board temperature
drops below acceptable limit. If condition persists, provide
shade for the equipment side of the hot tub.
FREEZE PROTECTION
A potential freeze condition has been detected. No action is
required. Pump(s) operate until the hot tub is out of danger.
Note: This error commonly occurs when the hot tub is first filled
because tap water is often very cold.
Communication between the control panel and/or remote con-
trol panel and circuit board is faulty. Contact your dealer or ser-
vice organization.
"WATCHDOG" (Hot tub is deactivated). A problem has been
detected which could cause damage to the hot tub or its com-
ponents. Contact your dealer or service organization.
OPEN SENSOR (heater disabled) OR SHORTED SENSOR (hot
tub is deactivated). The high-limit temperature sensor is non-
functional. This must be repaired only by a dealer or qualified ser-
vice organization.
OPEN OR SHORTED SENSOR (heater disabled). The main
sensor is non-functional. This must be repaired only by a
dealer or qualified service organization.
CLOSED OR SHORTED FLOW SWITCH ON SYSTEM
STARTUP (system disabled). Flow switch is non-functional.
This must be repaired only by a dealer or qualified service
organization.
Page 36
ENGLISH