ERROR MESSAGE DEFINITION OF ERROR
COMMENTS
031 OPEN CIRCUIT JIB DOWN
A load of less than 70mA detected when jib down
circuit was energized
Check for faulty jib down solenoid
coil and wiring.
032
SHORTED CIRCUIT JIB
DOWN
Excessive load detected when jib down circuit
was energized.
Check for faulty jib down solenoid
coil and wiring.
033 OPEN CIRCUIT EXTEND
A load of less than 70mA detected in extend
circuit on power-up.
Check for faulty boom extend
solenoid coil/wiring.
034 SHORTED CIRCUIT EXTEND
Excessive load detected in extend circuit on
power-up.
Check for faulty boom extend
solenoid coil/wiring.
035 OPEN CIRCUIT RETRACT
A load of less than 70mA detected in retract
circuit on power-up.
Check for faulty boom retract
solenoid coil/wiring.
036
SHORTED CIRCUIT
RETRACT
Excessive load detected in retract circuit on
power-up.
Check for faulty boom retract
solenoid coil/wiring.
037
OPEN CIRCUIT PLATFORM
LEVEL UP
A load of less than 70mA detected in platform
level up circuit on power-up.
Check for faulty level up solenoid
coil/wiring.
038
SHORTED CIRCUIT
PLATFORM LEVEL UP
Excessive load detected in platform level up
circuit on power-up.
Check for faulty level up solenoid
coil/wiring.
039
OPEN CIRCUIT PLATFORM
LEVEL DOWN
A load of less than 70mA detected in platform
level down circuit on power-up.
Check for faulty level down
solenoid coil/wiring.
040
SHORTED CIRCUIT
PLATFORM LEVEL DOWN
Excessive load detected in platform level down
circuit on power-up.
Check for faulty level down
solenoid coil/wiring.
041
OPEN CIRCUIT PLATFORM
CW
A load of less than 70mA detected in platform
CW circuit on power-up.
Check for faulty boom rotate
solenoid coil/wiring.
042
SHORTED CIRCUIT
PLATFORM CW
Excessive load detected in platform CW circuit
on power-up.
Check for faulty boom rotate
solenoid coil/wiring.
043
OPEN CIRCUIT PLATFORM
CCW
A load of less than 70mA detected in platform
CCW circuit on power-up.
Check for faulty boom rotate
solenoid coil/wiring.
044
SHORTED CIRCUIT
PLATFORM CCW
Excessive load detected in platform CCW circuit
on power-up.
Check for faulty boom rotate
solenoid coil/wiring.
045
OPEN CIRCUIT TURNTABLE
CW
A load of less than 70mA detected in rotate CW
circuit on power-up.
Check for faulty rotate CW
solenoid coil/wiring.
046
SHORTED CIRCUIT
TURNTABLE CW
Excessive load detected in rotate CW circuit on
power-up.
Check for faulty rotate CW
solenoid coil/wiring.
047
OPEN CIRCUIT TURNTABLE
CCW
A load of less than 70mA detected in rotate CCW
circuit on power-up.
Check for faulty rotate CCW
solenoid coil/wiring.
048
SHORTED CIRCUIT
TURNTABLE CCW
Excessive load detected in rotate CCW circuit on
power-up.
Check for faulty rotate CCW
solenoid coil/wiring.
049
OPEN CIRCUIT OUTRIGGER
RETRACT
A load of less than 70mA detected in outrigger
retract circuit on power-up.
Check for faulty outrigger retract
solenoid coil/wiring.
050
SHORTED CIRCUIT
OUTRIGGER RETRACT
Excessive load was detected when Outrigger
Retract circuit was energized.
Check for faulty outrigger retract
solenoid coil/wiring.
051
OPEN CIRCUIT OUTRIGGER
EXTEND
A load of less than 70mA detected in outrigger
retract circuit on power-up.
Check for faulty outrigger extend
solenoid coil/wiring.
052
SHORTED CIRCUIT
OUTRIGGER EXTEND
Excessive load was detected in outrigger extend
circuit on power-up.
Check for faulty outrigger extend
solenoid coil/wiring.
053
OPEN CIRCUIT
LF OUTRIGGER
A load of less than 70mA detected in left front
outrigger circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
054
SHORTED CIRCUIT
LF OUTRIGGER
Excessive load was detected in left front
outrigger circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
055
OPEN CIRCUIT
RF OUTRIGGER
A load of less than 70mA detected in right front
outrigger circuit on power-up.
Check for faulty solenoid