Snapper 1694602 9247E, 11694602 9247E, 1694589 9560E, 1694597 9560M, 1694606 E9247, 1694590 1060E, 1694598 1060M, 1694603 10287E, 1694607 E10287, 1694591 1170E, 1694599 1170M, 1694604 11327E, 1694608 E11327, 1694592 1280E, 1694600 1280M, 1694605 12387E, 1694609 E Snow Blower User Manual


 
Regular Maintenance
18
CHECK / LUBRICATE FREE-HAND
LINKAGE
Check the function of the Free-Hand controls: the con-
trols should function as described in the CONTROLS
section. It is critical for the safe operation of the unit
that the controls disengage when released.
If the controls do not function properly, lubricate them. If
lubrication does not rectify the problem, see your dealer.
Under no circumstances should the unit be used if the
controls are not functioning properly.
Figure 16. Lubricate Free Hand Control
Figure 17. Lubricating the Auger Shaft Assembly
A. Grease Fittings C. Cotter Pins
B. Shear Pins D. Auger Assembly
A
B
D
C
LUBRICATING THE AUGER SHAFT &
ASSEMBLY
1. Remove cotter pin (C, Figure 17) and shear pin (B).
2. Use a grease gun and squirt several shots of grease
into grease fitting (A).
3. Rotate auger assembly (D) several times to distribute
the grease evenly. Repeat step 2.
4. Reinstall shear pin (B) and cotter pin (C).
5. Repeat procedure for other side.
A
B
D
C
Figure 15. Lubricate Free-Hand™ Control Linkage
A. DO NOT Lubricate Deflector Control
A
IMPORTANT NOTE
It is very important that grease fittings on the auger shaft
are lubricated regularly. If auger rusts to shaft, damage to
worm gear may occur if shear pins do not break.