(4) Check the wiring through ZCT on the IDLE
CONTROL UNIT BOARD.
A) Single Voltage Type
Make sure that an output wire from main coil
is passing through the ZCT on the IDLE
CONTROL UNIT.
B) Dual Voltage Type
Check that two output wires (black wire and
red wire) from main coils are passing through
the ZCT on the IDLE CONTROL UNIT in the
same direction.
ZCT
UNIT
OUTPUT
WIRE
J
Fig. 11-14
(5) Checking the IDLE CONTROL UNIT
Check the resistance between six leads of IDLE CONTROL UNIT with circuit tester.
\
IDLE CONTROL UNIT
TES-
Fig. 11-15
Tester Polarity
LIGHT BLUE (FUSE)
LIGHT BLUE
RED
20-50kQ
20-50kQ
UGHT BLUE (FUSE)
UGHT BLUE
RED
Langer than 190kQ
Langer than 85kQ Langer than 85kQ
03
2-16kQ
Table 11-4
NOTE : Take & 10% tolerance on above resistance value.
If the measurement differs largely from momral value, the IDLE CONTROL UNIT is defective.
Replace with a new one.
- 75 -