TROUBLESHOOTING
Troubleshooting Symptoms
Engine Will Not Turn Over
Engine Turns Over, but Will Not Start
POSSIBLE CAUSE SOLUTION
Starter recoil damage Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Low battery voltage Recharge the battery to 12.8V DC
Starter motor damaged Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Internal engine damage Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
POSSIBLE CAUSE SOLUTION
Out of fuel Refuel
Low Oil Repeat Pre-operation Inspection
Water is present in fuel Drain the fuel system and refuel
Old or non-recommended
fuel
Drain the fuel system and refuel
Fouled or defective spark
plug
Inspect spark plug and replace if needed
No spark to spark plug Inspect spark plug, verify engine switch is ON
Water or fuel in crankcase Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Low battery voltage Recharge the battery to 12.8V DC
Mechanical failure Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Is the fuel valve on Turn the fuel valve on.