Polaris P3000iE Portable Generator User Manual


 
35
OPERATION
Safe Operating Precautions
Power Management
Total Running (Rated) Watts = 2000
Additional Starting Surge Watts = 1400
Total Generator Output Required = 3400
Ensure the combined electrical rating of the powered device(s) do not
exceed the maximum allowed by the generator. Never exceed the
maximum power rating of the generator. Power levels between rated and
maximum may be used for no more than 30 minutes.
DC Operation
Connecting the Battery Charging Cable (included)
The battery emits explosive hydrogen gas during normal operation. A
spark or flame can cause the battery to explode with enough force to kill
or cause serious injury. Wear protective clothing and eye protection when
charging a battery.
Battery posts, terminals, and related accessories contain lead and lead
components. Wash hands after handling.
To prevent the possibility of creating sparks near the battery, connect the
charging cable first to the generator then to the battery. Disconnect the
cable first at the battery.
The battery contains sulfuric acid (electrolyte). Contact with skin or eyes
may cause severe burns. Wear protective clothing and a face shield. If
electrolyte gets on your skin, flush with water. If electrolytes get in your
eyes, flush with water for at least 15 minutes and call a physician.
Electrolyte is poisonous. If swallowed, drink large quantities of water or
milk and follow with milk of magnesia or vegetable oil and call a physician.
Keep out of reach of children.
DEVICE
RUNNING
(RATED) WATTS
ADDITIONAL
STARTING (SURGE)
WATTS
Microwave oven 1000 1400
Coffee maker 1000 0