Polaris P3000iE Portable Generator User Manual


 
55
MAINTENANCE
Battery
Battery Safety
Always disconnect the negative (black) cable first when removing the
battery. Always connect the negative (black) cable last during installation.
Failure to properly connect/disconnect battery cables may result in an
explosion and cause serious injury or death.
Battery electrolyte contains sulfuric acid which is poisonous and can
cause serious burns. Avoid contact with eyes, skin, and clothing. Ensure
proper protective gloves, goggles, and clothing are worn. If eyes are
exposed, flush with water for 15 minutes and seek medical attention. If
external contact, flush with water. If ingested, drink large quantities of
water or milk. Follow with milk of magnesia, beaten egg, or vegetable oil.
Seek immediate attention.
Overheating of battery may cause an explosion, and severe injury or
death. Stop charging if the battery becomes very warm to the touch. Allow
battery to completely cool before resuming charging.
Avoid spilling of electrolyte. Damage to equipment may result.
Immediately wash off any electrolyte spills with a solution of one
tablespoon baking soda and one cup water.
Accessing the Battery
Open the service door to gain access to the battery, see page 16 for
location. Before performing any inspection or maintenance on the
battery, ignition switch and fuel valve lever should be positioned to OFF
Battery Cleaning
1. Using a stiff wire brush, remove corrosion from the battery
terminals and electrical connections.
2. Wash with a solution of one tablespoon baking soda and one cup
water.