Polaris P3000iE Portable Generator User Manual


 
20
CONTROLS AND FEATURES
DC Receptacle and Fuse
The DC receptacle is protected from
an overload with a fuse. If the DC
circuit is overloaded, the 5 amp fuse
(F1) will blow and power to the DC
receptacle will cease. The red light
on the DC panel will illuminate. The
fuse is located to the left of the
receptacle and is accessed by
snapping open the access door.
Replace the fuse with one of the
same capacity. Using a higher rated
fuse may cause damage to the
generator alternator.
The DC receptacle (F2) may be used for charging 12 volt automotive-
type batteries only. It is not designed to operate DC motors. Output
voltage is 15-30V. DC output will vary according to the position of the
Smart throttle switch.
AC Receptacles
Two AC receptacles (I) provide two
connections for properly rated AC
appliances. The two AC receptacles
are rated at 20 amps.