Pentair Quasar Swimming Pool User Manual


 
REV. F 1-6-05 7 P/N 98748000
WARNING
Do not attach or hang anything but this cord from the cord cap
through the hole in the body to the transformer housing.
Attaching or hanging items from this location can result in
failure to the body or the pool wall which can result in serious
personal injury and/or property damage.
5. Reinstall the snap-on cord cap to the stripped end of the cord
leaving 1/4 inch black insulation protruding into the cap with
the strain relief positioned as illustrated in Figure 13.
NOTE
Strain relief must be reinstalled at the end of the outer insulation
jacket. This will leave the two insulated conductors extending from the
inside of the snap end of the cord cap.
6. Strip the insulation back 1/4 inch on the two insulated
conductors and install the two wire connectors provided into
the end of each insulated conductor using a crimping pliers.
7. Connect the wire connectors from the bulb assembly to the
wire connectors attached to the snap-on cord cap.
NOTE
There is no polarity (no positive or negative) to the wires, either connection will work.
8. Snap the cap onto the end of the body and turn so that the
electrical cord is pointing down.
9. Cut off the cord with the 3-prong plug seven (7) in. from where it
exits the transformer box; see Figure 9. Discard the remaining cord
and plug.
10. Insert the cord from the plug through the smooth hole and then
insert the cord through the
threaded hole. Slide the cord
from the light assembly into
the angled slot on the junction
box bottom. Make sure the
cord by the transformer box
starts by the deep end of the
angled slot; see Figure 14.
Figure 12.
Pool Wall
Run cord
along wall.
Snap-on Cord Cap
Figure 13.
Strain
Relief
Press Together
Press Together
Figure 11.
Figure 14, Rear view
of transformer assy.