Pentair NT Series Hot Tub User Manual


 
P/N 472235 Rev. E 4-15-05
24
DIGITAL DISPLAY TEMPERATURE CONTROLLER (DDTC)
REMOTE
POOL
SPA
OFF
POWER
PRESSURE SW
THERMOSTAT
HEATING
SERVICE
REMOTE BUTTON
POOL BUTTON
SPA BUTTON
OFF BUTTON
TEMP. UP
TEMP. DOWN
SPA AND POOL
TEMPERATURE
SET BUTTONS
SYSTEM
INDICATOR
LIGHTS
PRESS ANY ARROW ONCE TO
CHECK SET TEMPERATURE
TEMPERATURE SETTING
POOL SPA
The DDTC board, shown in Figure 26, is a digital temperature controller capable of controlling the pool, spa
or both to a minimum temperature of 65° F. (below 65° F. display reads "Off") and a maximum of 104° F.
The DDTC board also functions as a system status indicator, using LED lights and programmed error codes.
During normal operation, the DDTC will display the current temperature of the water returning to the
heater, depending on which mode has been selected, “Pool” or “Spa”. This is accomplished by a thermister
(sensor) on the inlet port of the water header of the heater and working in conjunction with the internal
microprocessor controlling the operation of the heater.
Changing the desired pool or spa temperature is easily done by simply depressing the appropriate up or
down arrow until the display reads the desired set-point temperature. For example, set pool to 78° F. and the
spa to 104° F., when releasing the up or down arrow the display will flash once then return to the current
temperature.
At any time, you wish to know the temperature setting of the pool or spa, simply press the appropriate up or
down arrow, the display will flash once and display the set-point temperature for three (3) seconds, then
flash once again and return to the current temperature.
Section IV. Operation
Figure 26.