North Star M268180M Pest Control Equipment User Manual


 
Operation - Using the Sprayer (continued)
24
01542
Primin
g
va
l
ve
l
ever
Priming
hos
e
01542
Priming valve
Step Three: Operate the sprayer.
WARNING
ALWAYS wear personal protective equipment as directed on the
chemical label when spraying.
Long pants and sleeves, chemical-resistant gloves, and eye protection are
st rongly recommended. Addit ional protective gear may be required
depending on the particular pesticide.
1. Re vie w safe ty
information
Re vie w the “O peration – Important Safe ty Information” related to Chemical
Application Safety and ATV Vehicle Handling Safety provided in this manual.
2. Wear personal
protective
equipment
Wear personal protective equipment as dire cted on the chemical label.
Warning: Wear additional personal protective equipment if you will be
spraying overhead or fogging. You will be exposed to much more pesticide
fallout in these applications. Wear chemical resistant head and neck protection,
full face mask or half face mask with sealed goggles, and consider using a
dust /mist respirator.
3. Open priming
valve
Turn priming valve lever so that it is in-line with the priming hose.
4. Turn on power Turn on the power to the sprayer.
1. Verify the battery power cord is connected to the remote switch power cord
and that the remote switch power cord is connected to the pump power cord.
2. Turn the remote switch to the “ON” position.
Note: The pump will start automatically when power is turned on. Running
the pump dry will void all warranties.
5. Ensure flow
through priming
hose
Once chemical is flowing through the priming hose, close the priming valve.