5
www.napoleongrills.com
Propane Cylinder Installaon: Set cylinder into hole in boom shelf. Tighten strap over cylinder to secure it
in place.
Cylinder Connecon: Ensure the gas regulator hose is kink free. Remove the cap from the cylinder fuel valve.
Insert the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand ghten clockwise. Do not use tools.
Leak test all joints prior to using the pao torch. A leak test must be performed annually and each me a
cylinder is hooked up or if a part of the gas system is replaced.
If this torch is to be connected directly to a house propane gas supply line, follow the instrucons for the
natural gas hook-up. Ensure that the supply pressure is 11 inches water column.
Natural Gas Hook-Up: These connecons must be made by a licensed gas er. This natural gas pao torch
is supplied with a gas supply hose (complete with a quick disconnect) designed for natural gas and cered
for outdoor use. The pao torch is designed to operate at an inlet pressure of 7 inches water column. Pip
ing and
valves upstream of the quick disconnect are not supplied. The installaon must comply with CAN B149.1
Natural Gas and Propane installaon code in Canada, or to the Naonal Fuel Gas Code, ANSI Z223.1 in the
United States. The gas supply pipe must be sucient to supply this 31,000 BTU/hr pao torch.
The quick disconnect must not be installed in an upward direcon and a readily accessible manual shut-o
valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The ared end of the
hose must be connected to the ng on the end of the control valve as illustrated in the Natural Gas Hose
Aachment diagram. Tighten using two wrenches. (Do not use thread sealer/pipe dope.) Leak test all joints
prior to using the gas torch.
WARNING!
• The installaon must be performed by a licensed gas er, and all connecons must be leak tested
before operang the pao torch.
• Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe dope on
any hose connecon.
• Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a re.
• Leak test all the connecons using a soap and water soluon as per the leak tesng instrucons found in
the manual.
• The outdoor cooking gas appliance and its individual shuto valve must be disconnected from the gas
supply piping system during any pressure tesng of that system at test pressures in excess of 0.5 psi (3.5 kPa).
• The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its
individual manual shuto valve during any pressure tesng of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
Loop Strapping through slots in
boom shelf and secure over top
of propane tank as illustrated