Multiquip TLG-12SPX Portable Generator User Manual


 
PAGE 38 — TLG-12SPX — PARTS AND OPERATION MANUAL (STD) — REV. #4 (03/08/05)
A
0
40
60
75
20
Figure 26. Ammeter (No Load)
Figure 25. Voltage Adjust Control Knob
7. The ammeter (Figure 26) will indicate zero amps with no
load applied. When a load is applied, this meter will
indicate the amount of current that the load is drawing
from the generator’s alternator.
5. The generator's frequency meter (Figure 23) displays
the 60 cycle output frequency in HERTZ.
Figure 24. Voltage Meter (Volts)
6. The generator's voltage meter (Figure 24) displays the
120 VAC in VOLTS. If the voltage is not within the
specified frequency tolerance, use the voltage
adjustment control knob (Figure 25) to increase or
decrease the desired voltage.
Figure 23. Frequency Meter (Hz)
TLG-12SPX — SHUTDOWN PROCEDURE
ENGINE SHUTDOWN
To shutdown the generator, use the following procedure:
8. Set the circuit breaker to “ON”. Observe the generator's
ammeter (Figure 27) and verify it reads the anticipated
amount of current with respect to the load. The ammeter
will only display a current reading if the load is in use.
9. The generator will run until manually stopped or an
abnormal condition occurs.
Figure 27. Ammeter (Load)
A
0
40
60
75
20
1. Turn off all equipment attached to generator. Switch
the Circuit Breaker to ‘OFF’ .
2. Turn the throttle handle to the left and push in.
3. Let the engine cool by running it for 3-5 minutes with no
load applied.
4. Turn the key to ‘STOP’ position and remove the key.