LT12DAB LIGHT TOWER • OPERATION MANUAL — REV. #0 (06/03/11) — PAGE 23
Light tower is placed on secure level ground with chock
blocks underneath each wheel to prevent the light tower
from rolling.
Outriggers have been fully extended to prevent the trailer
from tipping.
Light tower trailer support stands have been positioned
properly and the trailer is level.
Lamps have been adjusted to desired position.
Light tower trailer frame has been grounded correctly.
Lamps do not interfere with any overhead obstructions.
Lamp power cables have been plugged into the
appropriate receptacles (J1-J4) on the T-Bar assembly.
Follow instructions below to correctly install the power
cable plugs.
a. Locate the 4 key-lock female 3-pin DIN connectors
on the T-bar. See Figure 10.
Figure 10. Location of Female Connectors
CAUTION
NEVER start the engine with any circuit breakers in
the ON position.
DANGER
ALWAYS make sure the area above
light tower is open and clear of
overhead power lines and other
obstructions. The tower extends in
excess of 30 ft. (9 meters). Contact
with overhead power lines or other
obstructions could result in equipment
damage, serious injury or death!
KEY-LOCK
FEMALE
CONNECTORS
INSPECTION
b. Locate the slot or key (A) on each female connector
as shown in Figure 11.
Figure 11. Female Connector
c. On the corresponding male connector, locate the
key tab (B) as shown in Figure 12.
Figure 12. Male Connector
d. Align the key tab (B) on the male connector with
the slot or key (A) on the female connector and
press together until fully seated.
e. Secure the connector by screwing the knurled
locking nut of the male connector to the threaded
portion of the female connector to ensure
good contact between the two connectors. See
Figure 13.
Figure 13. Cable Connectors
B
J1
J2
J3
J4
LOCKING
NUT