GENERATOR OUTPUTS

A wide range of voltages are available to supply voltage
for many different applications. Voltages are selected by
applying jumpers (6) to the 
(Figure 12). To obtain some of the voltages as listed in
Table 7 (see below) will require a fine adjustment using
the voltage regulator (VR) control knob located on the
control panel.

The  (Figure 12) is located on
the control box, behind the generator control panel. This
board has been provided for ease of voltage selection.
Figure 12. Voltage Change-Over Board

 attempt to place jumper plates on the voltage
 while the generator is in operation.
There exist the possibility of electrocution, electrical
shock or burn, which can cause severe bodily harm
or even death!








208V 220V 240V 416V 440V 480V
 120V 127V 139V 240V 254V 277V



120V
Line-Neutral
N/A N/A
240V
Line-Line
N/A N/A

Table 8 shows the maximum amps the generator can
provide.  exceed the maximum amps as listed.


DCA300SSC
DCA300SSCU
 
Single Phase 120 Volt 666.7 amps (4 wire)
Single Phase 240 Volt 333.3 amps (4 wire)
Three Phase 240 Volt 722 amps
Three Phase 480 Volt 361 amps