Multiquip DCA20spxu2 Portable Generator User Manual


 
DCA20SPXU2 SERVPRO
®

GENERATOR START-UP PROCEDURE (MANUAL)

1. Place the  circuit breakers
(Figure 24) in the OFF position prior to starting the
engine.
Figure 24. Main, Aux. and GFCI
Circuit Breakers (OFF)
2. Connect the load to the  or the output
 as shown in Figure 12. These load
connection points can be found on the output terminal
panel and the output terminal panel’s hard wire hookup
panel.
3. Tighten terminal nuts securely to prevent load wires
from slipping out.
4. Close all engine enclosure doors (Figure 25).
Figure 25. Engine Enclosure Doors

The engine’s exhaust contains harmful emissions.
 
Direct exhaust away from nearby personnel.

 manually start the engine with the 
or auxiliary circuit breakers in the  (closed) position.
INCORRECT
CORRECT

1. Place the   in the 
position to start the engine (Figure 26) position.
Figure 26. MPEC Control Switch
(Manual Position)
2. Verify that the engine running status LED on the
MPEC module (Figure 27) is lit (ON) after the engine
has started
Figure 27. Engine Running (LED ON)
3. The generator’s frequency meter (Figure 28) should
be displaying the 60 cycle output frequency in 
Figure 28. Frequency Meter
4. The generator’s AC-voltmeter (Figure 29) will display
the generator’s output in 
Figure 29. Voltmeter
AUT
O
MANUAL
OFF/RESET
AUTO
MANUAL
OFF/RESET
LOW OILPRESSURE
HIGHCOOLANT TEMPERATURE
OVERCRANK
OVERSPEED
ENGINE RUNNING
MOOOOO-20001Q
Hz
V