DCA-100SSJU — PARTS AND OPERATION MANUAL (STD)— REV. #2 (05/03/01) — PAGE 53
ENGINE SHUTDOWN
To shutdown the generator, use the following procedure:
1. Switch both the MAIN, GFCI and LOAD circuit breakers
(Figure 66) to the “OFF” position.
2. Set the engine speed switch (Figure 67) to the idle
(low) position.
4. Let the engine cool by running it for 3-5 minutes with no
load applied.
5. Turn the Auto-Off/Reset-Manual switch from the MPEC
to “OFF/Reset” position (Figure 69).
7. Remove the load from the UNV terminal strip.
Figure 66. Main, GFCI and Load
circuit breakers
Figure 67. Engine Speed Switch
DCA-100SSJU — GENERATOR SHUTDOWN PROCEDURE
Figure 69. Off/Manual Auto Switch
3. If the engine is equipped with the engine throttle lever,
turn and push to ‘IDLE’ position (Figure 68).
Figure 68. Engine Throttle Lever (IDLE)
6. If the engine is equipped with the engine throttle lever,
turn the key to ‘’STOP’ position (Figure 70).
Figure 70. Engine Starter Switch (STOP)
Table of Contents