Multiquip DCA-100SSJU Portable Generator User Manual


 
DCA-100SSJU PARTS AND OPERATION MANUAL (STD) REV. #2 (05/03/01) PAGE 41
Voltage Selector Switch- Single Phase 240/120V
Position
The following are additional voltages available when the
voltage selector switch is in the single phase 240/120V
position. (See Figure 36 below)
Single Phase, 240 Volt
The following connection, with the voltage selector switch
locked into the single phase 240/120V position (See
Figure 36), will offer SINGLE PHASE power at 240V. After
hooking up the hard wires to the lugs as shown in figure 38
below, use the Voltage Regulator Knob to fine tune to
240V. (See Figure 37)
Single Phase: 120 Volt
The following connection, with the voltage selector switch
locked into the single phase 240/120V position (See
Figure 36), will offer SINGLE PHASE power at 120V. After
hooking up the hard wires to the lugs as shown in figure 39
below, use the Voltage Regulator Knob to fine tune to
120V. (See Figure 37).
FIGURE 36. Voltage Selector Switch 240/120V Single Phase
Position
FIGURE 38. Hard Wire Hookup for Single Phase 240 volt
FIGURE 39. Hard Wire Hookup for Single Phase, 120 volt
FIGURE 37. Voltage
Regulator Knob located
on the control panel
DCA-100SSJU OUTPUT TERMINAL PANEL OVERVIEW
Table of Contents