Monessen Hearth dst30 Patio Heater User Manual


 
6 43D0122
NATURAL GAS
Milli-Volt Pressure
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max. 10 1/2" w. c.
Min. 5" w.c.
PRODUCT FEATURES AND SPECIFICATIONS
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Milli-Volt Pressure
Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Max. 13" w.c.
Min. 11" w.c.
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
DST30NV MILLI-VOLT 38,000 24,000
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Milli-Volt control has four (4) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
ON - Valve position to turn ON/OFF log set with remote, switch and/or thermostat.
HI/LOW - Variable position to control fl ame height (heat output).
PILOT
The gas log heater is fi tted with a specially designed safety pilot light (ODS assembly) which senses the amount of oxygen
available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot
can only be relit when adequate fresh air is available.
THERMAL GENERATOR
The milli-volt gas log pilot is fi tted with a milli-volt generator to provide power for remote activation.
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
DST30PV MILLI-VOLT 38,000 31,000