10 43D0122
WARNING
Height of Restriction (X) Minimum Depth of Fireplace/Firebox
No restriction 20
1
/4"
0.5 to 1.5" 24"
Greater than 1
1
/2" to 3" 26"
Greater than 3: ANY BARRIER GREATER THAN THREE INCHES (3")
PLACED IN FRONT OF THE GAS LOG SET IS NOT
RECOMMENDED BY THE MANUFACTURER.
PLACEMENT IN A FIREPLACE WITH A RESTRICTIVE BARRIER
IMPORTANT INFORMATION FOR THE INSTALLATION OF THIS GAS LOG SET
The following are guidelines for placing a gas log set in a fi replace that has a restrictive barrier along the bottom front opening
of the fi replace. Some examples of barriers are glass/screen door frames and sunken/recessed fi replaces.
Barriers such as the bottom of a glass door frame placed in
front of a gas log set can change the air fl ow characteristics
of the fi replace which in turn can cause the unit to overheat
and malfunction.
Glass door frames
with adjustable
louvers should have
the louvers fully
open while the unit is
in operation.
Height of restrictive barrier
caused by glass door frames,
recessed fi replaces, etc. from
the base or bottom surface of
the unit. (Refer to Table).
Depth of fi replace/fi rebox.
(Refer toTable).
Figure 3 - Reference Drawing of a DST Log Set in an Enclosure
NOTE: Non combustible material such as refractory brick may be used to line the fl oor of the fi replace
in order to raise the height of the gas log set in relation to a restrictive barrier. If the unit is raised, the
minimum height dimension listed in the homeowner’s manual must not be exceeded.
NOTE: If the log set is equipped with a remote receiver, a restrictive barrier may reduce the battery life
by increasing the ambient temperature inside the fi replace. Placement of the receiver outside of the
fi replace will extend the battery life.
X