. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drive Module Power Requirements
Drive Module Site Preparation Guide 23
FC-1 10x Drive Module and E2400 10x Command Module
The AC power source must provide the correct voltage, current, and frequency specified
on the manufacturer’s nameplate. Internal AC power units for rackmount cabinets must
be able to handle the power requirements for these units (Table 12).
Table 12 FC-1 10x and E2400 10x Power Requirements
Item Unit of Measure Requirement
Circuit Breaker 3.0 A (slow-blow fuse per power supply)
Drive Module and
Command Module
AC Power
USA International
Nominal Voltage 90 to 136 VAC 198 to 264 VAC
Frequency 50/60 Hz 50/60 Hz
Idle Current 3.39 A 1.45 A
Maximum Operating Current 3.53 A 1.50 A
Maximum Surge Current (10-
drive spin up)
5.19 A 2.10 A