33
WARNING! Isolate the electrical and water supplies before removing the cover. Mains
electricity connections are exposed when the cover is removed.
1. Remove the three cover retaining screws, the cover and the service tunnel.
2. Remove the hose from the outlet connector and loosen the connection to the
inlet connector.
3. Remove the six screws that hold the switch assembly, heater tank, flow regulator
assembly and inlet connector.
Flow Regulator Assembly/Switch Assembly- Removal and
Installation
Screws
Cover
Service Tunnel
Shower
Screw
4. Remove all wiring from the spade connections on the switch assembly.
Note! Using long nose pliers, gently squeeze the lever lock and pull the
spade connection off the switch assembly.
Spade Connection
Lever Lock