John Deere BZ100157 Compact Loader User Manual


 
Installation Instructions
OUZXMAG,00020A0 –19–13SEP05–1/1
Connecting Inoculant Dosing Device
ZX1037996 –UN–13SEP05
A—Connector for inoculant dosing device
To enable the dosing device system, the connector (A)
MUST be connected to the relevant connector of inoculant
dosing device control unit in the following manner (refer to
table for connector (A) pin connections).
Tx wire
1
of dosing device connector to Rx wire
2
of
wiring harness AZ101120 connector (A).
GND wire
3
of dosing device connector to GND wire of
wiring harness AZ101120 connector (A).
Rx wire of dosing device connector to Tx wire of wiring
harness AZ101120 connector (A).
Connector (A) Pin Connections
Pin Number Wire
Pin #A .......................................... 589—Tx
Pin #B .......................................... 590—GND
Pin #C ......................................... 591—Rx
1
Tx wire: Means wire that transmits the signal
2
Rx wire: Means wire that receives the signal
3
GND wire: Means ground wire
Z103757 (13DEC06)
21
Installation Instructions
011507
PN=23