Jacuzzi J - LXL Hot Tub User Manual


 
43
LX Collection
14.3 Panel Displays ICE
Freeze Protection - A potential freeze condition has been
detected. No action is required. Jets Pump 1 and heater
will activate to circulate and warm water through the plumbing until spa is
out of danger. See “Winterizing” (page 39).
14.4 Panel Displays SN1
Open sensor (heater is disabled) or shorted sensor (spa
is deactivated). The high-limit temperature sensor is not
functioning. Contact your authorized Jacuzzi dealer or
qualified service technician.
14.5 Panel Displays SN2
Open or shorted sensor (heater disabled). The
temperature sensor is not functioning. Contact your
authorized Jacuzzi dealer or qualied service technician.
14.6 Panel Flashes FL1 or FL2
A ashing “FL1” display means the ow switch is
malfunctioning open, the lter cartridge is excessively
dirty or an “air lock” condition has occurred at the
circulation pump intake. A ashing “FL2” display means
the ow switch is malfunctioning closed. In either case,
the spa heater will deactivate and jets pump #1 may
also deactivate. To correct condition perform the following:
1. Verify water level is above all jets but below lowest pillow. Add water
if necessary.
2. Check for clogged or dirty lter cartridge (Sec. 12.1, page 33).
3. Purge “air lock” from circulation pump intake by removing lter
cartridge. Hold your garden hose over the lter cartridge wall tting
while using a rag as a seal around hose end. Ask a helper to turn
on water for 30 seconds, then turn off. Reinstall lter cartridge and
check spa (Sec. 12.1, page 33).
4. If the circulation pump is not running, turn power off at the main
breaker, then turn power back on. This will reset the circulation pump
priming cycle. Once the pump is primed, the error should clear.
5. If problem persists, contact your authorized Jacuzzi dealer.
14.7 Panel Displays OH
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)

!
Water temperature is above acceptable limits. DO NOT ENTER SPA!
Water temperature has reached 112°F (44°C) and the low
speed jets pump 1 and optional circulation pump (when
equipped) has activated to circulate water through heater.
Contact your authorized Jacuzzi dealer or qualied service technician.