LX Collection
An optional chemical feeder is available through your
authorized Jacuzzi dealer that installs under the lter cap
(#2472-673). Always remove the chemical feeder cap and
feeder (when used) during the lter cleaning process by
turning the cap handle counterclockwise. Reinstall the cap
and feeder back onto the lter cartridge after the lter
cleaning process is complete. It is recommended that latex
gloves be used to avoid touching the chemical feeder
during the lter cleaning process.
Note: When used, the chemical feeder MUST remain on the circulation
pump lter cartridge! This lter cartridge is the one with the grid across
the wall tting as shown (right).
TO SPA OFF BEFORE CLEANING THE FILTER
CARTRIDGES!
Note: Refer to steps A-J on following page for
complete lter cleaning/replacement instructions.
A
DANGER: TURN POWER TO SPA OFF! TO DECREASE
OPERATE SPA WHEN FILTER IS NOT PROPERLY INSTALLED
OR IF SKIMMER ASSEMBLY IS DAMAGED OR ALTERED!
B
(Spa Shell)
Tilt cover forward to
access lter cartridges.
(The skim shield is
connected by spring
clips, use caution so the
lid does not snap back.)
C
Remove skimmer bag
and lter skimmer from
clips, then clean out
debris. Replace the lter
skimmer about every
three months, depending
on spa use.
D
Rotate each lter
cartridge handle
counterclockwise to
unthread from mating
wall tting.
Filter
Skimmer
Skimmer
Bag