Jacuzzi J - 480 Swimming Pool Vacuum User Manual


 
Page 14
J-400 Series
BLK
RED
RED
RED
BLK
BLK
1
2
Figure-C
TB1
to Circuit
Board
Power In
Green
TB3
1
2
BLUE
BLUE
BROWN
BROWN
Figure-D
TB1
to Circuit
Board
Power In
Green
TB3
All North American 240V Models:
240 VAC, 3-Wire Connection 60 Hz
All Export Models:
230 VAC, 3-Wire Connection 50 Hz
7.0 Power Requirements
Jacuzzi® spas are designed to provide optimum performance and
exibility of use when connected to their maximum electrical service.
They are congured at the factory. The most common electrical
connections are listed below:
All North American 60Hz Models: 240VAC/50A**
All Export 50Hz Models: 230VAC/30A**
If you prefer, your qualied technician can perform a minor circuit board
modication that allows the hot tub to operate on a different electrical
service (see table footnotes below).
North American J-460/J-465/J-470/J-480 Models (60Hz)
Voltage: 240 VAC 240 VAC 240 VAC
Max. Current Draw: 23A 36A 45A
Frequency: 60 Hz 60 Hz 60 Hz
Number of Wires: 3 3 3
Circuit Breaker (2-Pole): 30A* 50A** 60A***
*
In 30A conguration, the heater will not operate while either jets
pump is running.
** In 50A conguration, the heater will not operate while both jets
pumps are running. This is the factory setting.
***
In 60A conguration the heater will operate while both jets pumps
are running.