J-200
it. For optimum ltration benets, always leave this valve in position A
when the spa is covered and select positions B or C for maximum jet per-
formance during spa use.
10.7 Air Controls
Certain jet systems have their own air control. Each control
introduces air into the water lines that supply that specic jet
group. Simply turn the air control of choice counterclockwise
to open or clockwise to close. To minimize heat loss, all air controls
should be closed when the spa is not in use.
10.8 Optional Audio System (J-230 to J-280)
Spas equipped with the optional Jacuzzi audio system
offer enhanced enjoyment. These models include
an integrated AM/FM/CD receiver with high-quality marine speakers for
unsurpassed sound quality and long-life.
11.0 Automatic Filtration Cycles
The control system activates a programmable “Standard” or “Economy”
ltration cycle to remove debris from your spa. These cycles use the low
speed jets pump 1 and lter cartridge to quickly clear “skim” the water
of debris and minimize their “bathtub ring” affect while the spa is in use
or during a programmed lter cycle. Models equipped with the optional
24-hour circulation pump offer the added benet of 24-hour ltration for
pennies a day! The circulation pump is not programmable. Apart from their
ltration benet, each ltration mode also effects the operation of the spa
heater. Refer to Sections 11.1 and 11.2 for details.
r Models Without
Circulation Pump Option (All Models)
Standard ltration/heating modes (F1-F3) are typically selected by
customers in cold climates where heat up times are extended due to lower
ambient temperatures. In either of these modes, the water temperature is
regulated by the set temperature, low-speed jets pump 1 and heater which
turns on as needed. After the programmed set temperature is reached, the
heater and low speed pump turn off, only to turn back on during a heat call
or during the next programmed ltration/heating cycle.
For Models With
Standard ltration/heating modes (F0-F3) are typically selected by
customers in cold climates where heat up times are extended due
to lower ambient temperatures. In either of these modes, the water
temperature is regulated by the set temperature, 24-hour circulation
pump and heater which turns on as needed. After the programmed set
temperature is reached, the heater turns off and the circulation pump
continues to operate 24-hours to lter and clean your spa.
28