Jacuzzi GQ99000 Landscape Lighting User Manual


 
Jacuzzi
©
Chromatherapy: Installation and Operation Page 2 of 5 GQ99000 • 07-08
Lens cable (1-4)
Figure 3. Hole for Control Panel
detaiL
1/2 inch
5/32 inch1-1/16 inch
Figure 4. Hole for Chromatherapy Lamp(s)
1-5/8 inch
Caution: The panel and lamp(s) require modular cables from
behind. Make sure the proposed location of the panel and lamp(s)
will not cause cables to interfere with the bath plumbing
The control panel and each lamp must be mounted on a minimum
at surface space of the bath shell, see Table 1, Mounting Surface
Requirements.
Table 1. Mounting Surface Requiements
EQUIPMENT FLAT MOUNTING SURFACE
------------------------------------------------------------------------
Control panel 3 x 2 inches
Lamp (each) 2-1/2 by 2-1/2 inches
Next, consider the following cable lengths, starting with the control
box. See Table 2, Cable Lengths.
Table 2. Cable Lengths
CABLE LENGTH
--------------------------------------------------------
Control box cable 32 inches
Control panel cable 72 inches (6 feet)
Chromatheraphy lamp 84 inches (7 feet)
The control box must be mounted on a stud beam or secure wall
within 32 inches of the GFCI power outlet. The outlet must be a
minimum of 4 inches above the oor. In addition it must be located
no further than the length that the modular control cable or any
lamp cable may extend.
Once the location of the control box has been determined, you
may determine the location of the control panel and the lamp(s),
and prepare to drill a hole for each item.
Control Panel
Before marking the inside of the bath shell, place masking tape
over the entre area of the proposed hole. The tape will help
prevent chipping of the acrylic.
Writing on the tape, use a pointed marker to indicate the outline of
the hole for the control panel, see Figure 3. The control panel is
2-1/2 by 1-1/2 inches and requires a minimum of 3 by 2 inch at
mounting surface. Carefully mark the center of the hole.
Also mark the 5/32 inch notch at the right side of the diameter,
and mark the center of the notch. It is critical to measure the hole
and notch precisely.
Chromatherapy Lamp
Use a marker to indicate on the inside of the bath shell where the
lamp(s) will be located
Caution: Before marking the inside of the bath shell, place
masking tape over the entire area of the proposed hole, to help
prevent chipping of the acrylic.
Use a marker to indicate the location of the Chromatheraphy
lamp(s). The lamp is 2 inch diamerter and requires a minimum
of 2-1/2 diameter at mounting surface. (Locate as many lamps
as are intended for installation.) Indicate a hole for 1-5/8 inch
diameter, see Figure 4.