6.3 Troubleshooting
The application of white lithium grease to the glide pads must be done every six months to keep the tub in good working order.
If problems are not remedied, contact technical support at 1-800-668-2337, Extension 2.
SYMPTOMS FAULTS SOLUTION
Hydromassage System
System will not start No electrical power to tub Check and reset breaker
Switch air hose disconnected Reconnect hose to switch and controller
System is ineffective Water deposits in whirlpool jets Disassemble, inspect and clean whirlpool jets
System is noisy Whirlpool jets are turned on without water
completely covering the jet assemblies
Turn off the whirlpool jets. Add water to the tub to completely cover the
jet assemblies and test the whirlpool function again.
Tub Operation
No water flow Water supply turned off/no electrical con-
nection
Turn on water supply/check and reset breaker
Restricted water flow Water temperature control valve Inspect and clean the water temperature control valve. Refer to the Moen
service manual at www.moen.com. Search for Model 3371 ExactTemp