Husqvarna 1018855-26 Chainsaw User Manual


 
66 – English
ELECTRICAL SYSTEM
Checking the generator
Connect the ohm meter to the cylinder
(point A1) and point B. The ohm meter
should read 0.9-1.3 ohm.
Replace a generator that has higher or
lower values.
Connect the ohm meter to points B and C.
The ohm meter should read 3-4 ohm.
Replace the handle loop that has a higher
value.
Connect the ohm meter to points C and D.
The ohm meter should read 0.7-2.5 ohm.
Replace a heat loops that has higher
values.
Check the handle loop
Checking the heat loops in the rear handles
A1
B
B
C
Connect the ohm meter across the switch.
The ohm meter should read more than
1000 ohm with the switch in position "0".
The ohm meter should read, at the highest,
0.1 ohm with the switch in position "1".
Checking the power switch
D
C
Eng, p 40-82 96-09-13, 10.2566