Grizzly G0639 Log Splitter User Manual


 
-14-
Model G0639 22-Ton Hydraulic Log Splitter
24. Install the high pressure hose onto the pump
pressure fitting (
Figure 16), making sure the
O-ring stays in place
.
25. Connect the control lever (Figure 16) to the
control valve linkage with the clevis pin
.
26. Remove the plastic cap from the tank return
fitting (
Figure 17), oil and install an 11 x
2.4mm O-ring on the end of the fitting.
27. Using a screwdriver, unthread the plastic plug
from the low pressure return hose (
Figure
17).
28. Install the low pressure return hose onto the
tank return fitting (
Figure 17), making sure
the O-ring stays in place
.
23. Using a screwdriver, unthread the plastic plug
from the high pressure hose (
Figure 16).
29. Pull the tank vent cap (Figure 18) off, fill the
hydraulic tank with 2.5 gallons of hydraulic
oil, and reinstall the cap
.
Figure 17. Low pressure hose and tank fitting.
Tank
Return
Fitting
Low Pressure
Return Hose
Figure 18. Tank vent cap.
Tank
Vent /Fill
Cap
30. Refer to the Briggs & Stratton owner's manual
to select your required oil type, locate the fill
plug (Figure 19), and fill the engine with the
required engine oil.
Figure 19. Engine oil fill plug.
Engine
Oil Fill
Plug
Figure 16. High pressure hose and control lever.
Control
Lever and
Cotter Pin
High
Pressure
Hose