Genie DPL-30S Utility Vehicle User Manual


 
16 Genie DPL Super Series Part No. 82799
Operator’s Manual Second Edition • First Printing
FUNCTION TESTS
Test Outrigger Interlock
17 Twist to release the red Emergency Stop button
at the platform controls.
18 Push and hold the control activate button and
rotate the up/down switch in the direction of
intended travel.
Result: The up/down function should operate.
19 Unscrew one leveling jack until the
corresponding interlock display light turns off.
20 Push and hold the control activate button and
rotate the up/down switch in the direction of
intended travel.
Result: The up/down function should not
operate.
21 Return the leveling jack to the previous setting
and check the bubble level.
22 Repeat the procedure for each outrigger.
Test Auxiliary Platform Lowering
- AC & DC Models
23 Raise the platform slightly.
24 Disconnect the power source from the machine.
25 Turn the key switch to ground control.
26 Push in the auxiliary platform lowering button at
the ground controls.
Result: The platform should lower.
27 Connect the power source to the machine.
28 Turn the key switch to platform control.
29 Raise the platform approximately 6 in / 15 cm.
30 Disconnect the power source from the machine.
31 Push and hold the control activate button and
rotate the up/down switch in the down direction.
Result: The platform should lower.
32 Connect the power source to the machine.
Test Manual Lowering
33 Raise the platform slightly.
34 Activate the manual lowering lever.
Result: The platform should lower.