Genie DPL-30S Utility Vehicle User Manual


 
10 Genie DPL Super Series Part No. 82799
Operator’s Manual Second Edition • First Printing
Pre-operation Inspection
o Be sure that the operator’s, safety and
responsibilities manuals are complete, legible
and in the storage container located in the
platform.
o Be sure that all decals are legible and in place.
See Decals section.
o Check for battery fluid leaks and proper fluid
level. Add distilled water if needed. See
Maintenance section.
o Check for hydraulic oil leaks and proper oil level.
Add oil if needed. See Maintenance section.
Check the following components or areas for
damage, improperly installed or missing parts and
unauthorized modifications:
o Electrical components and wiring
o Coil cord (if equipped)
o Hydraulic power unit, hoses, fittings and
cylinders
o Manual lowering lever
o Platform end guard rail, platform side guard
rails and platform entry gate
o Guard rail lock handles
o Sequencing cables and pulleys
o Lifting chains and idler wheels
o Nuts, bolts and other fasteners
o Mast and mast braces
PRE-OPERATION INSPECTION
o Breather cap
o Outriggers, leveling jacks and footpads
o Guard rail lift arm
o Platform entry ladder
Check entire machine for:
o Dents or damage
o Corrosion or oxidation
o Crack in welds or structural components
o Inspect and clean battery terminals and all
battery cable connections.
o Be sure that all structural and other critical
components are present and all associated
fasteners and pins are in place and properly
tightened.