Emerson CF3400AP Outdoor Ceiling Fan User Manual


 
READ AND SAVE THESE INSTRUCTIONS
Installation Instruction on
New CSA Hanging Device
Always properly install the ceiling fan mounting plate to a structural ceiling joist that is capable of
reliably supporting at least 50 pounds.
INSTALLATION INSTRUCTIONS
1. Slip the loop of the short steel support cable onto the flat
washer, lockwasher and 2” lag screw (supplied). Attach
the short steel support cable through the center hole of
the outlet box into the supporting joist by securely
tightening the flat washer, lockwasher and 2” lag screw
(Figure 1). The support cable lag screw must be installed
such that it is structurally independent of the outlet box.
Pre-drill the support joist with a 9/64” diameter drill to
prevent splitting the joist.
2. Pull the electrical supply wires and support cable through
the center opening of the ceiling cover (Figure 2).
3. Install the ceiling cover and hanger bracket together onto
the outlet box using the two screws supplied with the
ceiling fan. Discard the screws that were supplied with
the electrical box. The hanger bracket will nest into the
ceiling cover between the raised guides on the bottom
surface of the cover. The center hole of the ceiling cover
provides visual access to view installation of the outlet
box screws into the threaded mounting holes of the box
(Figure 3).
4. Pull the electrical supply wires and support cable through
the opening on the back side of the hanger bracket for
installation of the fan’s hanger ball.
PRELIMINARY PROCEDURES FOR
EXTRA SUPPORT HANGING SYSTEM
SHORT STEEL
SUPPORT CABLE
JOIST
2" LAG SCREW
FLAT WASHER
LOOP
CENTER HOLE
LOCKWASHER
FLAT WASHER,
LOCKWASHER, &
2" LAG SCREW
DRYWALL CEILING
SHORT STEEL
SUPPORT CABLE
OUTLET BOX
ELECTRIC
OUTLET BOX
Figure 1
Turning off wall switch is not sufficient.
To avoid possible electrical shock, be sure
electricity is turned off at the main fuse box before
wiring. All wiring must be in accordance with
National and Local codes and the ceiling fan must
be properly grounded as a precaution against
possible electrical shock.
WARNING
MOUNTING SCREW (2)
TAB
HANGER BRACKET
CEILING
COVER
Figure 2
To avoid possible fire or shock, do not pinch electrical
wires between the ceiling cover and hanger bracket, or the
electrical box and the ceiling cover.
WARNING