Cold start:
Move the ON/OFF (I/O) switch (2) to position “I”.
Turn the starting lever (6) to the START position.
Press the fuel pump (5) several (7-10) times to supply fuel to
the carburetor.
Assume the starting position (see above under Starting posi-
tion).
Pull the starter cable by the grip (3) out slowly until you feel
resistance (the piston is now before top dead center).
Pull quickly and powerfully until the engine starts.
Caution: Never pull the starter cable out more than about 50
cm (20“), and guide it back slowly by hand.
As soon as the engine is running, grasp the grip (the safety cutoff
(1) is actuated by the palm of the hand) and tap the throttle (4).
The starting lever (6) will move to the RUN position and the
engine will run in idle.
Warm starting:
Move the ON/OFF (I/O) switch (2) to position “I” and start the
engine. If necessary push the fuel pump (5) a few times.
Switching off the engine
Move the ON/OFF (I/O) switch (2) to position “O” ( ).
Adjusting the carburetor (idle)
Thecarburetorisaninjectionmodelwithxednozzles.This
makesadjustmentoftheidleandmainnozzlesuperuous,and
these are impossible on this model.
If necessary, the idle speed can be adjusted with the adjusment
screw (8).
Idle speed correction is necessary if the blade moves in
idle (i.e. when the throttle is not actuated).
The blade must be completely stationary in idle!
Use a screwdriver (7, blade width 4 mm, part no. 944 340 001)
for this adjustment.
Let the engine warm up for 3-5 minutes before adjusting the
carburetor.
Avoid high engine speeds!
Adjusting the idle speed
Turning the adjustment screw (8) counter-clockwise:
Idle speed goes down.
Turnign the adjustment screw clockwise:
Idle speed goes up.
Caution: If the blade still does not come to a stop in idle
even after idle speed adjustment, do not work with the
trimmer under any circumstances. Take it to a DOLMAR
service centre!
The gure shows HT-2556 D.
These operations are identical for the HT-2576 E.