Dimplex Shower Outdoor Shower User Manual


 
SECTION 1
Unpacking and important notices
Contents
1 x Shower Unit
1 x Showerhead
1 x Flexible Hose
1 x Slider Rail Tube
1 x Slider Rail Brackets
1 x Height adjuster
1 x Screw pack
1 x Soap dish
1 x Showerhead key
IMPORTANT NOTICES
PLEASE READ BEFORE ATTEMPTING
TO INSTALL THE SHOWER UNIT
1) The shower unit must be installed by a
suitably qualified person and conform
to IEE Regulations and National Water
Council Bylaws.
2) The shower must only be connected
to a 15mm mains cold water supply.
Do not connect the unit to the cold
water supply of a header tank.
3) The minimum recommended running
water pressure to which the shower
heater may be connected is 15lb/sq in
(1bar); running pressure of 8 litres/minute;
maximum static pressure recommended
150lb/sq in (10 bar).
4) The shower unit must not be fitted
where it may be exposed to frost, for
example in an outdoor shower area. The
shower must not be used if suspected of
being frozen. Please note: Frost damage
is not covered by the guarantee.
5) Do not use Plumbers jointing compound.
Use of plumbers jointing compounds
invalidates the guarantee.
Complete all plumbing connections
before making any electrical connections.
The outlet of the shower unit must only be
connected to the hose and showerhead
supplied with the unit. Use of other
components will invalidate the warranty.
Always switch off at the isolating switch
when the shower is not in use.
To comply with National Water Council
bylaws a double check valve must be
fitted where it is possible that the shower-
head may come into contact with used
water e.g. in the shower tray or bath.
Do not operate power tools in a wet envi-
ronment. It is recommended that any power
tools operated in the bath or shower area are
supplied via a Residual Current Device (RCD).
WARNING! THIS APPLIANCE MUST BE EARTHED.
This shower is for connection to a
230V-240V/50Hz mains electricity supply.
SECTION 2
Installation
Typical instantaneous electric shower
installation
DIMENSIONS UNPACKING AND IMPORTANT NOTICES / INSTALLATION
HIGH
LOW
COLD
LOW
PRESSURE
AUTO
RESET
TEMPERATURE
S
T
O
P
610mm
218mm
339mm
Double pole heater switch wall mounted in
accordance with local authority regulations
Seperate permanently
connected supply
from consumer unit
Isolating
stop tap
Dimplex electric
water heater
Cold
water
mains
supply
2 3
Dimp13292-Shower inst aX4 5/5/04 2:08 pm Page 3