Cub Cadet 20HP Enforcer 44, 22HP Enforcer 48, 23HP Enforcer 54 Lawn Mower User Manual


 
19
5.
Figure 8
Spindle
Changing the Spindle Assembly
a. Jack up the front of the mowing deck about
one foot and block it in that position.
b. Make sure the blade clutch is disengaged.
c. Remove the deck cover.
d. Remove the drive belts. (See 4. Changing
Blade Drive Belts.)
e. Remove the cutter blade. (See 2. Chang-
ing a Blade.)
f. Using a wrench or socket ratchet remove
four hex nuts, and the four hex head cap
screws. Remove the spindle assembly.
g. Reverse the process to install the spindle
assembly.
C.Hydrostatic Drive System
1.
Your zero turn riding mower is equipped with
dual integrated hydrostatic pumps, motors, and
gear reduction transaxles
.
The fluid level in the
expansion tank must be maintained at 1/2” to 1”
above the bottom of the tank. See Figure 9.
Hydrostatic
Transaxles
Figure 9
expansion tank
Note:
See Maintenance Schedule, Section E,
page 23.
D.Electrical Circuit
Danger:
Read General Safety Precautions Nos. 9 and 10.
1.
Battery:
The battery is located beneath the
operator’s seat. If so equipped, remove the
fillcaps and check the level of the liquid elec
-
trolyte in the battery every 50 operating hours.
If the level in any of the six cells has dropped
below the bottom of the split ring inside the fill
hole, refill the cell with distilled water. To keep
the outside of the battery clean, brush on a
strong solution of bicarbonate of soda and
water and rinse with clean water. Keep the
contacts and cable ends clean with a wire
brush and make sure the connections are
tight. Coat the terminals with petroleum jelly
to prevent corrosion.
2. Battery Removal
Warning:
When removing the cables from the battery
follow these steps to avoid a short between
the wrench and the frame.
a. Remove the negative (black) cable.
b. Remove the positive (red) cable.
c. Release the hold down straps.
d. Remove the battery without tipping.
3.
Battery Storage:
When storing the mower for
long periods of time the following guidelines
should be performed.
a. Disconnect the battery cables from the ter-
minals and remove the battery.
b. Clean the battery before storing. A dirty
battery will lose its charge over time.
c. Store the battery with a full charge. A dis-
charged battery will freeze (refer to the
table below).
Specific Gravity Freezing Temp (°F)
1.265 -71
1.250 -62
1.200 -16
1.150 5
1.100 16
d. Recharge battery when ever the specific
gravity value is less than 1.225
4. Installing the Battery
Note: The battery is delivered from the fac-
tory fully charged and filled with electrolyte.