Chauvet 6 Landscape Lighting User Manual


 
COLORado™ 6 User Manual 8 7/1/2009 4:46 PM
MALE/POWER INPUT
FEMALE/POWER
OUTPUT/LINKING
3. SETUP
AC Power
This fixture has an auto-switching switch-mode power supply that can accommodate a wide range of
input voltages. The only thing necessary to do before powering on the unit is to make sure the line
voltage you are applying is within the range of accepted voltages. This fixture will accommodate
100~240VAC, 50/60 Hz.
This fixture is designed for power linking from one COLORado™ to another COLORado™ fixture.
Each fixture ships with power extension cables (proprietary male-to-female IP66 connectors).
Note! All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for
a 0% to 100% switch
Warning! All fixtures must be connected to circuits with a suitable Earth Ground.
Depending on the application, the lighting fixture may require a different connector (terminator).
Please refer to the below factory-installed IP66 terminator wire color code if installing a wire
connector (terminator).
Please be aware: this fixture is warranted as IP66 outdoor rating. Removing the connector(s)
on this fixture or any other type of tampering with the case or cable(s) may void the IP66
outdoor rating. However, this will not void the standard 2-year warranty that all Chauvet DMX
fixtures carry, provided the operating voltages are within the proper range.
WIRE
CONNECTION
Brown
AC Live
Blue
AC Neutral
Green/Yellow
AC Ground
CONNECTION
PIN
AC LIVE
1
AC NEUTRAL
2
GROUND(EARTH)
3