SYMPTOM(S)
POSSIBLE SOLUTION(S)
1 or more LEDs are not illuminating
Clean the fixture regularly to avoid any such failure. This fixture is
convection cooled, which means that if the surface is kept clean and
free of debris, then proper cooling will be allowed to occur
An LED may have failed, resulting in an open circuit. In this event,
all of the red, green, or blue in a single module will no longer
illuminate. This does not mean that all of the LEDs have failed, but
the circuit is wired in series.
An LED may have failed, resulting in a short circuit. In this event,
only the single LED which has failed will no longer function.
Note: In the event of LED failure, a replacement LED PCB assembly
may be purchased directly from Chauvet Part#: P222-C1LEDPC
1 or more LEDs are producing very low
output
Check that the lens assembly is installed properly. If the lens
assembly is not aligned properly over the LEDs, then they will not
project fully
See section on Lens Assembly Installation
Note: In the event of LED failure, a replacement LED PCB assembly
may be purchased directly from Chauvet Part#: P222-C1LEDPC
Breaker/Fuse keeps blowing
Check total load placed on the electrical circuit
Check for a short in the electrical wiring: internal and/or external
Device has no power
Check device’s fuse (internal)
Check for power on Mains
Check cable connections The COLORado™ IP66 cables must be
firmly connected for operation
Check for manual power off from the display by pressing and
holding down the {EXIT} button for more than 3 seconds
Note: In the event of autoswitching transformer failure, the unit can
be sent in for repair; however, a replacement part can be ordered
directly from Chauvet Part#: P140-C6ELTR
Fixture is not responding to DMX
Check Control Panel settings for correct addressing
Check DMX cables
Check polarity switch settings on the controller
Check cable connections The COLORado™ IP66 cables must be
firmly connected for operation
Call service technician
Note: In the event of Master PCB failure, a replacement PCB can be
ordered directly from Chauvet Part#: P170-C6MPCB
Loss of signal
Use only DMX cables
Install terminator
Note: Keep DMX cables separated from power cables or black lights
COLOR-CON Controller does not
function, or does not function properly
Make sure connector is firmly connected to device
The COLORado™ fixture must be in the correct mode in order to
properly respond to the COLOR-CON controller. The correct mode
is “CON” under “RUN” in the onboard Control Panel
Stand alone operation
This fixture has built-in, automatic programs that may be triggered
from the onboard Control Panel
Display reading: “warning heat”
The COLORado™ 6 features a thermal protection that will be
implemented in the event of over-heating. This can occur if the
fixture in not in an ideal location for the convection cooling to be
effective